Your Cart (0 items)
product

Sikadur®-42 MP Slow HC

(+15% Vat Included)

Sikadur®-42 MP Slow HC is a three-component, multipurpose epoxy grout that is moisture-tolerant and designed for use within a temperature range of approximately +20°C to +40°C.

    ส่งฟรีในกรุงเทพและปริมณฑล

    Guarantee Safe Checkout payment img

    What is Sikadur®-42 MP Slow HC?

    Sikadur®-42 MP Slow HC is a three-component, multipurpose epoxy grout with moisture-tolerant properties, designed for application at temperatures ranging from approximately +20°C to +40°C.

    Main Applications of Sikadur®-42 MP Slow HC

    Suitable for high-strength grouting and anchoring applications, such as:

    • Reinforcing steel, bolts, anchors, and steel rods

    • Bollards, fence posts, and handrails

    • Under baseplates and machinery foundations

    • Light and heavy machinery, including equipment subjected to impact and vibration

    • Bridge bearing supports and mechanical joints

    • Railway sleepers, railway tracks, and crane rails

    Key Features of Sikadur®-42 MP Slow HC

    • High early compressive strength

    • Supplied in ready-to-mix kits

    • Moisture tolerant

    • Non-shrink

    • Resistant to corrosion and chemicals

    • Resistant to impact and stress

    • High compressive strength

    • High vibration resistance

    • Low coefficient of thermal expansion

    Substrate Preparation

    Concrete and mortar should be more than 28 days old. The substrate must be sound, clean, dry or slightly damp, and free from:

    • Dust

    • Oil

    • Grease

    • Coatings

    • Loose cementitious materials

    • Standing water

    Steel surfaces should be prepared to Sa 2.5 standard. sikadur-42-mp-slowhc

    Mixing Method

    1. Mix Components A and B for approximately 30–60 seconds.

    2. Use a low-speed drill at approximately 300–450 rpm.

    3. Pour the mixture into a suitable container.

    4. Gradually add Component C.

    5. Continue mixing for approximately 3 minutes.

    6. Allow the mixture to stand for 2–3 minutes to reduce entrapped air bubbles.

    Avoid excessive mixing that may introduce too much air into the mixture. sikadur-42-mp-slowhc

    Application Method

    • Use properly sealed, leakproof formwork.

    • PE film or wax can be used as a release agent to prevent the grout from bonding to the formwork.

    • It is recommended to pour the grout from only one side or two sides to minimize air entrapment.

    • The grout level should be approximately 3 mm above the underside of the baseplate.

    • The clearance beneath the baseplate must be at least 12 mm.

    • If the gap exceeds 150 mm, the grout should be poured in layers, allowing the previous layer to cool and harden before applying the next layer.